| Version 4 (modified by , 14 months ago) ( diff ) | 
|---|
PDAFomi_set_localization
This page documents the routine PDAFomi_set_localization of PDAF-OMI. This routine has been added with PDAF V2.3.
This routine is used for the case that a user implements a user-provided alternative for the routine PDAFomi_init_dim_obs_l, which initializes the local observation information for PDAF-OMI in thisobs_l for a single local analysis domain.
This routine is for isotropic localization (for non-isotropic localization see PDAFomi_set_localization_noniso)
The routine has to be called in init_dim_obs_l_OBSTYPE in each observation module if a domain-localized filter (LESTKF/LETKF/LNETF/LSEIK/LKNETF)is used. 
| See the page on user-provided initialization of local observations for the full description of a user-provided routine to intialize local observations. | 
The interface is:
  SUBROUTINE PDAFomi_set_localization(thisobs_l, cradius, sradius, locweight)
    TYPE(obs_l), INTENT(inout) :: thisobs_l  ! Data type with local observation
    REAL, INTENT(in) :: cradius              ! Localization cut-off radius
    REAL, INTENT(in) :: sradius              ! Support radius of localization function
    INTEGER, INTENT(in) :: locweight         ! Type of localization function
Notes:
- The arguments are usually the same inputs as used when calling PDAFomi_init_dim_obs_l.