= init_obsvars_pdaf = The page documents the user-supplied call-back routine `init_obsvars_pdaf`, which was introduced with PDAF V3.0. The routine `init_obsvars_pdaf` (named `U_init_obsvars` inside PDAF) is a call-back routine that has to be provided by the user. The routine is used only with the ENSRF/EAKF. The routine is called by PDAF during the analysis step and has to provide the filter with a vector of observation error variances. The interface is the following: {{{ SUBROUTINE init_obsvars_pdaf(step, dim_obs_f, var_f) }}} with arguments: {{{ INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(in) :: dim_obs_f ! Dimension of full observation vector REAL, INTENT(out) :: var_f(dim_obs_f) ! vector of observation error variances }}} The variance vector `var_f` is for the full observation vector.