Changes between Version 10 and Version 11 of ImplementAnalysispf
- Timestamp:
- Jun 3, 2025, 5:31:42 PM (3 days ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
ImplementAnalysispf
v10 v11 52 52 == `PDAF_assimilate_pf` == 53 53 54 The general aspects of the filter-specific routines `PDAF_assimilate_*` have been described on the page [ ModifyModelforEnsembleIntegration Modification of the model code for the ensemble integration] and its sub-page on [InsertAnalysisStep inserting the analysis step]. The routine is used in the fully-parallel implementation variant of the data assimilation system. When the 'flexible' implementation variant is used, the routines `PDAF_put_state_*' is used as described further below. Here, we list once more the full interface. Subsequently, the full set of user-supplied routines specified in the call to `PDAF_assimilate_pf` is explained.54 The general aspects of the filter-specific routines `PDAF_assimilate_*` have been described on the page [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3 Modification of the model code for the ensemble integration]. The routine is used in the fully-parallel implementation variant of the data assimilation system. When the 'flexible' implementation variant is used, the routines `PDAF_put_state_*' is used as described further below. Here, we list once more the full interface. Subsequently, the full set of user-supplied routines specified in the call to `PDAF_assimilate_pf` is explained. 55 55 56 56 The interface when using the PF method is the following: … … 74 74 == `PDAF_put_state_pf` == 75 75 76 When the 'flexible' implementation variant is chosen for the assimilation system, the routine `PDAF_put_state_pf` has to be used instead of `PDAF_assimilate_pf`. The general aspects of the filter specific routines `PDAF_put_state_*` have been described on the page [ ModifyModelforEnsembleIntegrationModification of the model code for the ensemble integration]. The interface of the routine is identical with that of `PDAF_assimilate_pf` with the exception of the specification of the user-supplied routines `U_distribute_state` and `U_next_observation` are missing.76 When the 'flexible' implementation variant is chosen for the assimilation system, the routine `PDAF_put_state_pf` has to be used instead of `PDAF_assimilate_pf`. The general aspects of the filter specific routines `PDAF_put_state_*` have been described on the page [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3 Modification of the model code for the ensemble integration]. The interface of the routine is identical with that of `PDAF_assimilate_pf` with the exception of the specification of the user-supplied routines `U_distribute_state` and `U_next_observation` are missing. 77 77 78 78 The interface when using the PF method is the following: … … 85 85 == User-supplied routines == 86 86 87 Here, all user-supplied routines are described that are required in the call to `PDAF_assimilate_pf`. For some of the generic routines, we link to the page on [ ModifyModelforEnsembleIntegrationmodifying the model code for the ensemble integration].87 Here, all user-supplied routines are described that are required in the call to `PDAF_assimilate_pf`. For some of the generic routines, we link to the page on [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3 modifying the model code for the ensemble integration]. 88 88 89 89 To indicate user-supplied routines we use the prefix `U_`. In the tutorials in `tutorial/` and in the template directory `templates/` these routines exist without the prefix, but with the extension `_pdaf`. The files are named correspondingly. In the section titles below we provide the name of the template file in parentheses. … … 95 95 96 96 This routine is independent of the filter algorithm used. 97 See the page on [ InsertAnalysisStep#U_collect_statecollect_state_pdaf.F90 inserting the analysis step] for the description of this routine.97 See the page on [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3#U_collect_statecollect_state_pdaf.F90 inserting the analysis step] for the description of this routine. 98 98 99 99 … … 101 101 102 102 This routine is independent of the filter algorithm used. 103 See the page on [ InsertAnalysisStep#U_distribute_statedistribute_state_pdaf.F90 inserting the analysis step] for the description of this routine.103 See the page on [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3#U_distribute_statedistribute_state_pdaf.F90 inserting the analysis step] for the description of this routine. 104 104 105 105 … … 166 166 === `U_prepoststep` (prepoststep_ens_pdaf.F90) === 167 167 168 The routine has been described on the [ ModifyModelforEnsembleIntegration#U_prepoststepprepoststep_ens_pdaf.F90 page on modifying the model code for the ensemble integration] for the SEIK filter. For the PF, the interface is generally identical. For completeness, we repeat the description here.168 The routine has been described on the [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3#U_prepoststepprepoststep_ens_pdaf.F90 page on modifying the model code for the ensemble integration] for the SEIK filter. For the PF, the interface is generally identical. For completeness, we repeat the description here. 169 169 170 170 The interface for this routine is … … 227 227 228 228 This routine is independent of the filter algorithm used. 229 See the page on [ InsertAnalysisStep#U_next_observationnext_observation_pdaf.F90 inserting the analysis step] for the description of this routine.229 See the page on [wiki:OnlineModifyModelforEnsembleIntegration_PDAF3#U_next_observationnext_observation_pdaf.F90 inserting the analysis step] for the description of this routine. 230 230 231 231