Changes between Version 4 and Version 5 of ImplementAnalysis_3DVar_PDAF23


Ignore:
Timestamp:
Jun 10, 2025, 2:13:19 PM (16 months ago)
Author:
lnerger
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • ImplementAnalysis_3DVar_PDAF23

    v4 v5  
    6464== `PDAFomi_assimilate_3dvar` ==
    6565
    66 The general aspects of the filter (or solver) specific routines `PDAF_assimilate_*` have been described on the page [ModifyModelforEnsembleIntegration Modification of the model code for the ensemble integration] and its sub-page on [InsertAnalysisStep inserting the analysis step]. The routine is used in the fully-parallel implementation variant of the data assimilation system. When the 'flexible' implementation variant is used, the routines `PDAF_put_state_*` is used as described further below. Here, we list the full interface of the routine. Subsequently, the user-supplied routines specified in the call is explained.
     66The general aspects of the filter (or solver) specific routines `PDAF_assimilate_*` have been described on the page [wiki:ModifyModelforEnsembleIntegration_PDAF23 Modification of the model code for the ensemble integration] and its sub-page on [wiki:InsertAnalysisStep_PDAF23 inserting the analysis step]. The routine is used in the fully-parallel implementation variant of the data assimilation system. When the 'flexible' implementation variant is used, the routines `PDAF_put_state_*` is used as described further below. Here, we list the full interface of the routine. Subsequently, the user-supplied routines specified in the call is explained.
    6767
    6868The interface for using the parameterized 3D-Var is:
    … …  
    8989== `PDAFomi_put_state_3dvar` ==
    9090
    91 When the 'flexible' implementation variant is chosen for the assimilation system, the routine `PDAFomi_put_state_global` has to be used instead of `PDAFomi_assimilate_global`. The general aspects of the filter specific routines `PDAF_put_state_*` have been described on the page [ModifyModelforEnsembleIntegration Modification of the model code for the ensemble integration]. The interface of the routine is identical with that of `PDAF_assimilate_global` with the exception the specification of the user-supplied routines `U_distribute_state` and `U_next_observation` are missing.
     91When the 'flexible' implementation variant is chosen for the assimilation system, the routine `PDAFomi_put_state_global` has to be used instead of `PDAFomi_assimilate_global`. The general aspects of the filter specific routines `PDAF_put_state_*` have been described on the page [wiki:ModifyModelforEnsembleIntegration_PDAF23 Modification of the model code for the ensemble integration]. The interface of the routine is identical with that of `PDAF_assimilate_global` with the exception the specification of the user-supplied routines `U_distribute_state` and `U_next_observation` are missing.
    9292
    9393The interface when using one of the global filters is the following:
    … …  
    101101== User-supplied routines ==
    102102
    103 Here all user-supplied routines are described that are required in the call to `PDAFomi_assimilate_3dvar`. For some of the generic routines, we link to the page on [ModifyModelforEnsembleIntegration modifying the model code for the ensemble integration].
     103Here all user-supplied routines are described that are required in the call to `PDAFomi_assimilate_3dvar`. For some of the generic routines, we link to the page on [wiki:ModifyModelforEnsembleIntegration_PDAF23 modifying the model code for the ensemble integration].
    104104
    105105To indicate user-supplied routines we use the prefix `U_`. In the template directory `templates/` as well as in the tutorial implementations in `tutorial/` these routines exist without the prefix, but with the extension `_pdaf.F90`. The user-routines relating to OMI are collected in the file `callback_obs_pdafomi.F90`. In the section titles below we provide the name of the template file in parentheses.
    … …  
    112112This routine is independent of the filter algorithm used.
    113113
    114 See the page on [InsertAnalysisStep#U_collect_statecollect_state_pdaf.F90 inserting the analysis step] for the description of this routine.
     114See the page on [wiki:InsertAnalysisStep_PDAF23#U_collect_statecollect_state_pdaf.F90 inserting the analysis step] for the description of this routine.
    115115
    116116
    … …  
    119119This routine is independent of the filter algorithm used.
    120120
    121 See the page on [InsertAnalysisStep#U_distribute_statedistribute_state_pdaf.F90 inserting the analysis step] for the description of this routine.
     121See the page on [wiki:InsertAnalysisStep_PDAF23#U_distribute_statedistribute_state_pdaf.F90 inserting the analysis step] for the description of this routine.
    122122
    123123
    … …  
    126126This is a call-back routine for PDAF-OMI initializing the observation information. The routine just calls a routine from the observation module for each observation type.
    127127
    128 See the [wiki:OMI_Callback_obs_pdafomi documentation on callback_obs_pdafomi.F90] for more information.
     128See the [wiki:OMI_Callback_obs_pdafomi_PDAF23 documentation on callback_obs_pdafomi.F90] for more information.
    129129
    130130
    … …  
    134134This is a call-back routine for PDAF-OMI applying the observation operator to the state vector. The routine calls a routine from the observation module for each observation type.
    135135
    136 See the [wiki:OMI_Callback_obs_pdafomi documentation on callback_obs_pdafomi.F90] for more information.
     136See the [wiki:OMI_Callback_obs_pdafomi_PDAF23 documentation on callback_obs_pdafomi.F90] for more information.
    137137
    138138
    … …  
    182182This is a call-back routine for PDAF-OMI applying the linearized observation operator to the state vector. The routine calls a routine from the observation module for each observation type. If the full observation operator is lineaer the same operator can be used here.
    183183
    184 See the [wiki:OMI_Callback_obs_pdafomi documentation on callback_obs_pdafomi.F90] for more information.
     184See the [wiki:OMI_Callback_obs_pdafomi_PDAF23 documentation on callback_obs_pdafomi.F90] for more information.
    185185
    186186
    … …  
    189189This is a call-back routine for PDAF-OMI applying the adjoint observation operator to some vector inthe observation space. The routine calls a routine from the observation module for each observation type.
    190190
    191 See the [wiki:OMI_Callback_obs_pdafomi documentation on callback_obs_pdafomi.F90] for more information.
     191See the [wiki:OMI_Callback_obs_pdafomi_PDAF23 documentation on callback_obs_pdafomi.F90] for more information.
    192192
    193193
    … …  
    196196The routine has already been described for modifying the model for the ensemble integration and for inserting the analysis step.
    197197
    198 See the page on [InsertAnalysisStep#U_prepoststepprepoststep_ens_pdaf.F90 inserting the analysis step] for the description of this routine.
     198See the page on [wiki:InsertAnalysisStep_PDAF23#U_prepoststepprepoststep_ens_pdaf.F90 inserting the analysis step] for the description of this routine.
    199199
    200200
    … …  
    203203This routine is independent of the filter algorithm used.
    204204
    205 See the page on [InsertAnalysisStep#U_next_observationnext_observation_pdaf.F90 inserting the analysis step] for the description of this routine.
     205See the page on [wiki:InsertAnalysisStep_PDAF23#U_next_observationnext_observation_pdaf.F90 inserting the analysis step] for the description of this routine.
    206206