= Implementation of the Analysis step for the LSEIK filter = {{{ #!html

Implementation Guide

  1. Main page
  2. Adaptation of the parallelization
  3. Initialization of PDAF
  4. Modifications for ensemble integration
  5. Implementation of the analysis step
    1. Implementation for SEIK
    2. Implementation for LSEIK
  6. Memory and timing information
}}} [[PageOutline(2-3,Contents of this page)]] == Overview == For the analysis step of the LSEIK filter several operations related to the observations are needed. These operations are requested by PDAF by calling user-supplied routines. Intentionally, the operations are split into separate routines in order to keep the operations rather elementary as this procedure should simplify the implementation. The names of the required routines are specified in the call to the routine `PDAF_put_state_lseik` described below. With regard to the parallelization, all these routines are executed by the filter processes (`filterpe=1`) only. The following user-supplied routines for the SEIK filter are described on this page. (For completeness, we also repeat the generic routines that were described on the page [ModifyModelforEnsembleIntegration Modification of the model core for the ensemble integration]. * [#U_init_dim_obs_fullinit_dim_obs_full.F90 U_init_dim_obs_full]: The name of the user-supplied routine that provides the size of observation vector * [#U_obs_op_fullobs_op_full.F90 U_obs_op_full]: The name of the user-supplied routine that acts as the observation operator on some state vector * [#U_init_obs_fullinit_obs_full.F90 U_init_obs_full]: The name of the user-supplied routine that initializes the vector of observations * [#U_prodRinv_localA_prodrinva_local.F90 U_prodRinvA_local]: The name of the user-supplied routine that computes the product of the inverse of the observation error covariance matrix with some matrix provided to the routine by PDAF. This operation occurs during the analysis step of the LSEIK filter. * [#U_init_obsvarinit_obsvar.F90 U_init_obsvar]: The name of the user-supplied routine that provides a mean observation error variance to PDAF (This routine will only be executed, if an adaptive forgetting factor is used) Below the names of the corresponding routines in the template directory are provided in parentheses. The the routines in the example implementation have the same name but include '`_dummy_D`' in the name. == PDAF_put_state_lseik == The general espects of the filter specific routines `PDAF_put_state_*` have been described on the page [ModifyModelforEnsembleIntegration Modification of the model core for the ensemble integration]. The interface for the routine `PDAF_put_state_lseik` contains several routine names for routines that operate on the local analysis domains (marked by `_l` at then end of the routine name). In addition, there are names for routines that consider all available observations required to perform local analyses with LSEIK within some sub-domain of a domain-decomposed model (marked by `_full` at then end of the routine name). In case of a serial execution of the assimilation program, this will be all globally available observations. However, if the program is executed with parallelization, this might be a smaller set of observations. To explain the difference it is assumed for simplicity that a local analysis domain consists of a single vertical column of the model grid. In addition, we assume that the domain decomposition splits the global model domain by vertical boundaries as is typical for ocean models and that the observations are spatially distributed observations of model fields that are part of the state vector. Under these assumptions, the situation is the following: When a model uses domain decomposition, the LSEIK filter is executed such that for each model sub-domain a loop over all local analysis domains (e.g. vertical columns) that belong to the model sub-domain is performed. For the update of each single vertical column observations from some larger domain surrounding the vertical column are considered. If the influence radius for the observations is sufficiently small there will be vertical columns for which all relevant observations reside inside the model sub-domain of the process. However, if a vertical column is considered that is located close to the boundary to the model sub-domain, there will be some observations that don't belong spatially to the local model sub-domain, but to a neighboring model sub-domain. These observations nonetheless are required on the local model sub-domain. Thus, a simple way to handle this situation is to initialize for each process all globally available observations, together with their coordinates. While this method is simple, it can also become inefficient if the assimilation program is executed using a large number of processes. As for an initial implementation, it is usually not the concern to obtain the highest parallel efficiency, the description below assumes that 'full' refers to the global model domain. The interface when using the LSEIK filter is the following: {{{ SUBROUTINE PDAF_put_state_lseik(U_collect_state, U_init_dim_obs_full, U_obs_op_full, U_init_obs_full, & U_init_obs_local, U_prepoststep, U_prodRinvA_local, U_init_n_domains, & U_init_dim_local, U_init_dim_obs_local, U_g2l_state, U_l2g_state, U_g2l_obs, & U_init_obsvar, U_init_obsvar_local, status) }}} with the following arguments: * `U_collect_state`: The name of the user-supplied routine that initializes a state vector from the array holding the ensembel of model states from the model fields. This is basically the inverse operation to `U_distribute_state` used in `PDAF_get_state` * `U_init_dim_obs_full`: The name of the user-supplied routine that provides the size of observation vector * `U_obs_op_full`: The name of the user-supplied routine that acts as the observation operator on some state vector * `U_init_obs_full`: The name of the user-supplied routine that initializes the vector of observations * `U_init_obs_local`: The name of the user-supplied routine that initializes the vector of observations for a local analysis domain * `U_prepoststep`: The name of the pre/poststep routine as in `PDAF_get_state` * `U_prodRinvA_local`: The name of the user-supplied routine that computes the product of the inverse of the observation error covariance matrix with some matrix provided to the routine by PDAF. This operation occurs during the analysis step of the SEIK filter. * `U_init_n_domains`: The name of the routine that provides the number of local analysis domains * `U_init_dim_local`: The name of the routine that provides the state domains for a local analysis domain * `U_init_dim_obs_local`: The name of the routine that initializes the size of the observation vector for a local analysis domain * `U_g2l_state`: The name of the routine that initializes a local state vector from the global state vector * `U_l2g_state`: The name of the routine that initializes the part of the global state vector corresponding to the provided local state vector * `U_g2l_obs`: The name of the routine that initialized a local observation vector from a full observation vector * `U_init_obsvar`: The name of the user-supplied routine that provides a global mean observation error variance to PDAF (This routine will only be executed, if an adaptive forgetting factor is used) * `U_init_obsvar_local`: The name of the user-supplied routine that provides a mean observation error variance for the local analysis domain to PDAF (This routine will only be executed, if an adaptive forgetting factor is used) * `status`: The integer status flag. It is zero, if PDAF_get_state is exited without errors. == User-supplied routines == Here all user-supplied routines are described that are required in the call to `PDAF_put_state_lseik`. For some of the generic routines, we link to the page on [ModifyModelforEnsembleIntegration modifying the model code for the ensemble integration]. To indicate user-supplied routines we use the prefix `U_`. In the template directory `templates/` these routines are provided in files with the routines name without this prefix. In the example implementation in `testsuite/src/dummymodel_1D` the routines exist without the prefix, but with the extension `_dummy_D.F90`. In the section titles below we provide the name of the template file in parentheses. === `U_collect_state` (collect_state.F90) === This routine is independent from the filter algorithm used. See [ModifyModelforEnsembleIntegration#U_collect_statecollect_state.F90 here] for the description of this routine. === `U_init_dim_obs_full` (init_dim_obs_full.F90) === This routine is used by all local filter algorithms (LSEIK, LETKF). The interface for this routine is: {{{ SUBROUTINE init_dim_obs_full(step, dim_obs_f) INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(out) :: dim_obs_f ! Dimension of full observation vector }}} The routine is called at the beginning of each analysis step, before the loop over all local analysis domains is entered. It has to initialize the size `dim_obs_f` of the full observation vector according to the current time step. For simplicity, `dim_obs_f` can be the size for the global model domain. Some hints: * It can be useful to not only determine the size of the observation vector at this point. One can also already gather information about the location of the observations, which will be used later, e.g. to implement the observation operator. An array for the locations can be defined in a module like `mod_assimilation`. * The routine is similar to `init_dim_obs` used in the global filters. However, if the global filter is used with a domain-decomposed model, it only initializes the size of the observation vector for the local model sub-domain. This is different for the local filters, as the local analysis also requires observational data from neighboring model sub-domains. Anyway, one can base on an implemented routine `init_dim_obs` to implement `init_dim_obs_full`. === `U_obs_op_full` (obs_op_full.F90) === This routine is used by all local filter algorithms (LSEIK, LETKF). The interface for this routine is: {{{ SUBROUTINE obs_op_full(step, dim_p, dim_obs_f, state_p, m_state_f) INTEGER, INTENT(in) :: step ! Currrent time step INTEGER, INTENT(in) :: dim_p ! PE-local dimension of state INTEGER, INTENT(in) :: dim_obs_f ! Dimension of the full observed state REAL, INTENT(in) :: state_p(dim_p) ! PE-local model state REAL, INTENT(out) :: m_state_f(dim_obs_f) ! Full observed state }}} The routine is called during the analysis step, before the loop over the local analysis domain is entered. It has to perform the operation of the observation operator acting on a state vector that is provided as `state_p`. The observed state has to be returned in `m_state_f`. It is the observed state corresponding to the 'full' observation vector. Hint: * If the observation operator involves a global operation, e.g. some global integration, while using domain-decompostion one has to gather the information from the other model domains using MPI communication. * Analogously to the situation with `init_dim_obs_full`, the routine is similar to `init_dim_obs` used for the global filters. However, with a domain-decompoared model also here `m_state_f` will contain parts of the state vector from neighboring model sub-domains. To make these parts accessible, some parallel communication will be necessary (The state information for a neighboring model sub-domain, will be in the memory of the process that handles that sub-domain). The example implementation in `testsuite/dummymodel_1d` uses the function `MPI_AllGatherV` for this communication. === `U_init_obs_full` (init_obs_full.F90) === This routine is used by all local filter algorithms (LSEIK, LETKF). The interface for this routine is: {{{ SUBROUTINE init_obs_full(step, dim_obs_f, observation_f) INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(in) :: dim_obs_f ! Dimension of full observation vector REAL, INTENT(out) :: observation_f(dim_obs_f) ! Full observation vector }}} The routine is called during the analysis step before the loop over the local analysis domains is entered. It has to provide the full vector of observations in `observation_f` for the current time step. Hints: * As for the other 'full' routines: While the global counterpart of this routine (`init_obs`) has to initialize the observation vector for the local model sub-domain, the 'full' routine has to include observations that spatially belong to neighboring model sub-domains. As an easy choice one can simply initialize a vector of all globally available observations. === `U_init_obs_local` (init_obs_local.F90) === This routine is used by all local filter algorithms (LSEIK, LETKF). The interface for this routine is: {{{ SUBROUTINE init_obs_local(domain_p, step, dim_obs_l, observation_l) INTEGER, INTENT(in) :: domain_p ! Current local analysis domain INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(in) :: dim_obs_l ! Local dimension of observation vector REAL, INTENT(out) :: observation_l(dim_obs_l) ! Local observation vector }}} The routine is called during the analysis step during the loop over the local analysis domain. It has to provide the vector of observations for analysis of the local analysis domain of index `domain_p` in `observation_l` for the current time step. Hints: * For parallel efficiency the LSEIK is implemented in a way that first the full vectors are initialized. Thus, as `observation_f` has been initialized before `init_obs_local` is executed, the operations performed in this routine will be to select the part of the full observation vector that is relevant for the current local analysis domain. === `U_prepoststep` (prepoststep_seik.F90) === This routine can be identical to that used for the global SEIK filter. See [ModifyModelforEnsembleIntegration#U_prepoststepprepoststep_seik.F90 here] for the description of this routine. === `U_prodRinvA_local` (prodrinva_local.F90) === This routine is used by the local filters (LSEIK and LETKF). The interface for this routine is: {{{ SUBROUTINE prodRinvA_local(domain_p, step, dim_obs_p, rank, obs_p, A_p, C_p) SUBROUTINE prodRinvA_local(domain_p, step, dim_obs_l, rank, obs_l, A_l, C_l) INTEGER, INTENT(in) :: domain_p ! Current local analysis domain INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(in) :: dim_obs_l ! Dimension of local observation vector INTEGER, INTENT(in) :: rank ! Rank of initial covariance matrix REAL, INTENT(in) :: obs_l(dim_obs_l) ! Local vector of observations REAL, INTENT(inout) :: A_l(dim_obs_l, rank) ! Input matrix from analysis routine REAL, INTENT(out) :: C_l(dim_obs_l, rank) ! Output matrix }}} The routine is called during the loop over the local analysis domains in the analysis step. In the algorithm the product of the inverse of the observation error covariance matrix with some matrix has to be computed. For the SEIK filter this matrix holds the observed part of the ensemble perturbations for the local analysis domain of index `domain_p`. The matrix is provided as `A_l`. The product has to be given as `C_l`. This routine is also the place to perform observation localization. To initialize a vector of weights, the routine `PDAF_local_weights` can be called. The procedure is used in the example implementation and also demonstrated in the template routine. Hints: * the routine does not require that the product is implemented as a real matrix-matrix product. Rather, the product can be implemented in its most efficient form. For example, if the observation error covariance matrix is diagonal, only the multiplication of the diagonal with matrix `A_l` has to be implemented. * The observation vector `obs_l` is provided through the interface for cases where the observation error variance is relative to the actual value of the observations. === `U_init_obsvar` (init_obsvar.F90) === This routine is used by the global filter algorithms SEIK and ETKF as well as the local filters LSEIK and LETKF. The routine is only called if the adaptive forgetting factor is used (`type_forget=1` in the example impementation). The interface for this routine is: {{{ SUBROUTINE init_obsvar(step, dim_obs_p, obs_p, meanvar) INTEGER, INTENT(in) :: step ! Current time step INTEGER, INTENT(in) :: dim_obs_p ! PE-local dimension of observation vector REAL, INTENT(in) :: obs_p(dim_obs_p) ! PE-local observation vector REAL, INTENT(out) :: meanvar ! Mean observation error variance }}} The routine is called in the global filters during the analysis or by the routine that computes an adaptive forgetting factor (PDAF_set_forget). The routine has to initialize the mean observation error variance. For the global filters this should be the global mean. Hints: * For a model with domain-decomposition one might use the mean variance for the model sub-domain of the calling process. Alternatively one can compute a mean variance for the full model domain using MPI communication (e.g. the function `MPI_allreduce`). * The observation vector `obs_p` is provided to the rotine for the case that the observation error variance is relative to the value of the observations.